Manual Linear Stage: The MX-A - Series
The MX-A series is available as X-, XY-, Z-axis positioning stage. The MX-A series offers a wide range of platform sizes from 20 x 20 mm to 125 x 125 mm. All stages are made of aluminum and equipped with cross-roller bearings. They can be combined with rotation or lifting stages and use low-outgassing, vacuum-compatible lubricants. Depending on the model, the travel range varies between ± 3.2 mm and ± 12.5 mm.
Typical application areas include laboratory automation, optical alignment, standard precision applications, photonics, and general mechanical engineering.
Micrometer: 10 µm resolution
Fine Screw: 0.5 mm lead
Micrometer / Fine Screw
Center / Side
MX-S
Travel: ± 3.2 mm - ± 12.5 mmAvailable as X, XY and Z Axis. Combinable with other manual positioning stages for multi axis systems.
At a glance
All information at a glance – and in detail
on our website
www.gmteurope.eu
Key features
Key features, benefits and available engine optionsSpecification
Datasheet on accuracy, design & interfacesKey features
- Cross-roller bearing guide
- Aluminum, black anodized
- Clamping screw & lock nut
- Micrometer screw & fine-thread screw
- Available as X, XY, Z-axis
- For laboratory automation, optical alignment, standard precision applications, photonics, and mechanical engineering
MX-A - Series
X Axis for linear positioning
XY-Axis for 2-Dimensional positioning
Z-Axis for vertical positioning
Cross-roller cages provide exceptionally stable and backlash-free guidance thanks to rollers arranged at 90°. This precise roller configuration ensures high rigidity, smooth motion, and reliable load capacity in all directions.
Vernier scale, minimum reading of 10 µm
0.5 mm lead per rotation
Specification
| MX-A (X-Axis) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 25 | 30 | 40 | 50 | 60 | 70 | 80 | 100 | 120 | |
| Material | Aluminum, black anodized | |||||||||
| Platform Dimension | 20Â mm x 20Â mm | 25Â mm x 25Â mm | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 50Â mm x 50Â mm | 60Â mm x 60Â mm | 70Â mm x 70Â mm | 80Â mm x 80Â mm | 100Â mm x 100Â mm | 120Â mm x 120Â mm |
| Travel Stroke | ± 3.2 mm | ± 3.2 mm | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 12.5 mm | ± 12.5 mm | ± 12.5 mm |
| Load | 10 N | 10 N | 12 N | 20 N | 40 N | 50 N | 60 N | 100 N | 150 N | 200 N |
| Feeding Type | Micrometer / Fine Screw | |||||||||
| Feeding Position | Central / Side | |||||||||
| Micrometer: Min. Reading | 10 µm | |||||||||
| Fine Screw: Lead | 0.5 mm | |||||||||
| Straightness Accuracy | 3 µm | |||||||||
| Weight | 0.03 kg | 0.04 kg | 0.045 kg | 0.14 kg | 0.22 kg | 0.25 kg | 0.44 kg | 0.5 kg | 0.7 kg | 1.6 kg |
| MXL-A (X-Axis, thin type) | |||||
|---|---|---|---|---|---|
| 30 | 40 | 60 | 90 | 125 | |
| Material | Aluminum, black anodized | ||||
| Platform Dimension | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 60Â mm x 60Â mm | 90Â mm x 90Â mm | 125Â mm x 125Â mm |
| Travel Stroke | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 7.5 mm | ± 12.5 mm |
| Load | 30 N | 30 N | 50 N | 80 N | 150 N |
| Feeding Type | Micrometer | ||||
| Feeding Position | Central / Side | ||||
| Micrometer: Min. Reading | 10 µm | ||||
| Straightness Accuracy | 3 µm | ||||
| Weight | 0.04 kg | 0.13 kg | 0.3 kg | 0.45 kg | 1.1 kg |
| MY-A (XY-Axis) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 25 | 30 | 40 | 50 | 60 | 70 | 80 | 100 | 120 | |
| Material | Aluminum, black anodized | |||||||||
| Platform Dimension | 20Â mm x 20Â mm | 25Â mm x 25Â mm | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 50Â mm x 50Â mm | 60Â mm x 60Â mm | 70Â mm x 70Â mm | 80Â mm x 80Â mm | 100Â mm x 100Â mm | 120Â mm x 120Â mm |
| Travel Stroke | ± 3.2 mm | ± 3.2 mm | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 12.5 mm | ± 12.5 mm | ± 12.5 mm |
| Load | 10 N | 10 N | 12 N | 18 N | 40 N | 45 N | 60 N | 95 N | 143 N | 184 N |
| Feeding Type | Micrometer / Fine Screw | |||||||||
| Feeding Position | Central / Side | |||||||||
| Micrometer: Min. Reading | 10 µm | |||||||||
| Fine Screw: Lead | 0.5 mm | |||||||||
| Straightness Accuracy | 3 µm | |||||||||
| Weight | 0.06 kg | 0.08 kg | 0.09 kg | 0.28 kg | 0.44 kg | 0.5 kg | 0.88 kg | 1 kg | 1.4 kg | 3.2 kg |
| MYL-A (XY-Axis, thin type) | |||||
|---|---|---|---|---|---|
| 30 | 40 | 60 | 90 | 125 | |
| Material | Aluminum, black anodized | ||||
| Platform Dimension | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 60Â mm x 60Â mm | 90Â mm x 90Â mm | 125Â mm x 125Â mm |
| Travel Stroke | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 7.5 mm | ± 12.5 mm |
| Load | 30 N | 30 N | 50 N | 80 N | 150 N |
| Feeding Type | Micrometer | ||||
| Feeding Position | Central / Side | ||||
| Micrometer: Min. Reading | 10 µm | ||||
| Straightness Accuracy | 3 µm | ||||
| Weight | 0.08 kg | 0.23 kg | 0.5 kg | 0.85 kg | 2 kg |
| MZL-A (Z-Axis) | ||||||||
|---|---|---|---|---|---|---|---|---|
| 25 | 40 | 60 | 80 | |||||
| Material | Aluminum, black anodized | |||||||
| Platform Dimension | 25Â mm x 25Â mm | 40Â mm x 40Â mm | 60Â mm x 60Â mm | 80Â mm x 80Â mm | ||||
| Travel Stroke | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 12.5 mm | ||||
| Load | 5 N | 10 N | 20 N | 50 N | ||||
| Feeding Type | Micrometer | |||||||
| Feeding Position | Central / Side | |||||||
| Micrometer: Min. Reading | 10 µm | |||||||
| Straightness Accuracy | 3 µm | |||||||
| Weight | 0.06 kg | 0.2 kg | 0.45 kg | 0.8 kg | ||||
Accessories
General accessories
To the purchase of the MX-AÂ Series
Manual Linear Stage: The MX-A - Series
The MX-A series is available as X-, XY-, Z-axis positioning stage. The MX-A series offers a wide range of platform sizes from 20 x 20 mm to 125 x 125 mm. All stages are made of aluminum and equipped with cross-roller bearings. They can be combined with rotation or lifting stages and use low-outgassing, vacuum-compatible lubricants. Depending on the model, the travel range varies between ± 3.2 mm and ± 12.5 mm.
Typical application areas include laboratory automation, optical alignment, standard precision applications, photonics, and general mechanical engineering.
Micrometer: 10 µm resolution
Fine Screw: 0.5 mm lead
Micrometer / Fine Screw
Center / Side
MX-S
Travel: ± 3.2 mm - ± 12.5 mmAvailable as X, XY and Z Axis. Combinable with other manual positioning stages for multi axis systems.
At a glance
All information at a glance – and in detail
on our website
www.gmteurope.eu
Key features
Key features, benefits and available engine optionsSpecification
Datasheet on accuracy, design & interfacesKey features
- Cross-roller bearing guide
- Aluminum, black anodized
- Clamping screw & lock nut
- Micrometer screw & fine-thread screw
- Available as X, XY, Z-axis
- For laboratory automation, optical alignment, standard precision applications, photonics, and mechanical engineering
MX-A - Series
X Axis for linear positioning
XY-Axis for 2-Dimensional positioning
Z-Axis for vertical positioning
Cross-roller cages provide exceptionally stable and backlash-free guidance thanks to rollers arranged at 90°. This precise roller configuration ensures high rigidity, smooth motion, and reliable load capacity in all directions.
Vernier scale, minimum reading of 10 µm
0.5 mm lead per rotation
Specification
| MX-A (X-Axis) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 25 | 30 | 40 | 50 | 60 | 70 | 80 | 100 | 120 | |
| Material | Aluminum, black anodized | |||||||||
| Platform Dimension | 20Â mm x 20Â mm | 25Â mm x 25Â mm | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 50Â mm x 50Â mm | 60Â mm x 60Â mm | 70Â mm x 70Â mm | 80Â mm x 80Â mm | 100Â mm x 100Â mm | 120Â mm x 120Â mm |
| Travel Stroke | ± 3.2 mm | ± 3.2 mm | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 12.5 mm | ± 12.5 mm | ± 12.5 mm |
| Load | 10 N | 10 N | 12 N | 20 N | 40 N | 50 N | 60 N | 100 N | 150 N | 200 N |
| Feeding Type | Micrometer / Fine Screw | |||||||||
| Feeding Position | Central / Side | |||||||||
| Micrometer: Min. Reading | 10 µm | |||||||||
| Fine Screw: Lead | 0.5 mm | |||||||||
| Straightness Accuracy | 3 µm | |||||||||
| Weight | 0.03 kg | 0.04 kg | 0.045 kg | 0.14 kg | 0.22 kg | 0.25 kg | 0.44 kg | 0.5 kg | 0.7 kg | 1.6 kg |
| MXL-A (X-Axis, thin type) | |||||
|---|---|---|---|---|---|
| 30 | 40 | 60 | 90 | 125 | |
| Material | Aluminum, black anodized | ||||
| Platform Dimension | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 60Â mm x 60Â mm | 90Â mm x 90Â mm | 125Â mm x 125Â mm |
| Travel Stroke | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 7.5 mm | ± 12.5 mm |
| Load | 30 N | 30 N | 50 N | 80 N | 150 N |
| Feeding Type | Micrometer | ||||
| Feeding Position | Central / Side | ||||
| Micrometer: Min. Reading | 10 µm | ||||
| Straightness Accuracy | 3 µm | ||||
| Weight | 0.04 kg | 0.13 kg | 0.3 kg | 0.45 kg | 1.1 kg |
| MY-A (XY-Axis) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 20 | 25 | 30 | 40 | 50 | 60 | 70 | 80 | 100 | 120 | |
| Material | Aluminum, black anodized | |||||||||
| Platform Dimension | 20Â mm x 20Â mm | 25Â mm x 25Â mm | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 50Â mm x 50Â mm | 60Â mm x 60Â mm | 70Â mm x 70Â mm | 80Â mm x 80Â mm | 100Â mm x 100Â mm | 120Â mm x 120Â mm |
| Travel Stroke | ± 3.2 mm | ± 3.2 mm | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 6.5 mm | ± 12.5 mm | ± 12.5 mm | ± 12.5 mm |
| Load | 10 N | 10 N | 12 N | 18 N | 40 N | 45 N | 60 N | 95 N | 143 N | 184 N |
| Feeding Type | Micrometer / Fine Screw | |||||||||
| Feeding Position | Central / Side | |||||||||
| Micrometer: Min. Reading | 10 µm | |||||||||
| Fine Screw: Lead | 0.5 mm | |||||||||
| Straightness Accuracy | 3 µm | |||||||||
| Weight | 0.06 kg | 0.08 kg | 0.09 kg | 0.28 kg | 0.44 kg | 0.5 kg | 0.88 kg | 1 kg | 1.4 kg | 3.2 kg |
| MYL-A (XY-Axis, thin type) | |||||
|---|---|---|---|---|---|
| 30 | 40 | 60 | 90 | 125 | |
| Material | Aluminum, black anodized | ||||
| Platform Dimension | 30Â mm x 30Â mm | 40Â mm x 40Â mm | 60Â mm x 60Â mm | 90Â mm x 90Â mm | 125Â mm x 125Â mm |
| Travel Stroke | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 7.5 mm | ± 12.5 mm |
| Load | 30 N | 30 N | 50 N | 80 N | 150 N |
| Feeding Type | Micrometer | ||||
| Feeding Position | Central / Side | ||||
| Micrometer: Min. Reading | 10 µm | ||||
| Straightness Accuracy | 3 µm | ||||
| Weight | 0.08 kg | 0.23 kg | 0.5 kg | 0.85 kg | 2 kg |
| MZL-A (Z-Axis) | ||||||||
|---|---|---|---|---|---|---|---|---|
| 25 | 40 | 60 | 80 | |||||
| Material | Aluminum, black anodized | |||||||
| Platform Dimension | 25Â mm x 25Â mm | 40Â mm x 40Â mm | 60Â mm x 60Â mm | 80Â mm x 80Â mm | ||||
| Travel Stroke | ± 3.2 mm | ± 6.5 mm | ± 6.5 mm | ± 12.5 mm | ||||
| Load | 5 N | 10 N | 20 N | 50 N | ||||
| Feeding Type | Micrometer | |||||||
| Feeding Position | Central / Side | |||||||
| Micrometer: Min. Reading | 10 µm | |||||||
| Straightness Accuracy | 3 µm | |||||||
| Weight | 0.06 kg | 0.2 kg | 0.45 kg | 0.8 kg | ||||


Deutsch (Deutschland)